Nilan CT 300 4xG4 Filter set (Filtering material for frames)

Reference: NILCT300G4M

£7.39
Tax included delivery in 5-7 working days

Ex Tax: £6.16

Filter dimensions 500x230
Class EN779 G4x4
Class ISO16890 Coarse 65%
Protection level Basic: larger solid particles, dust, fluff.
Quantity of filters 4
Advantages check Low airflow resistance: longer servicing term, lower energy consumption.
check Made in the EU.
check Premium class certified synthetic filtering material (SANDLER AG, Germany)
check Tested according to ISO16890 at the accredited laboratory in Germany.
Remarks check The filter set is designed to protect the MVHR from bigger particles. If you want to clean the supply air from small particles such as pollen and smog, choose the F7 class supply air filter. It is available in our shop.

Volume discounts

Quantity Price You Save
3 £6.65 Up to £2.22
5 £5.91 Up to £7.39
10 £5.54 Up to £18.47
Quantity
In stock

                                              

NILCT300G4M

Data sheet

Manufacturer of MVHR
Nilan
Manufacturer
CleanFilter
Model
CT
Model size
300
Air handling unit
Nilan CT 300
Filter dimensions
500x230
Class EN779
G4x4
Class ISO16890
Coarse 65%
Protection level
Basic: larger solid particles, dust, fluff.
Quantity of filters
4
Advantages
Low airflow resistance: longer servicing term, lower energy consumption.
Made in the EU.
Premium class certified synthetic filtering material (SANDLER AG, Germany)
Tested according to ISO16890 at the accredited laboratory in Germany.
Manufacturer product number
7373372
Remarks
The filter set is designed to protect the MVHR from bigger particles. If you want to clean the supply air from small particles such as pollen and smog, choose the F7 class supply air filter. It is available in our shop.
Google category ID
3573
Product type
Filters for Air Handling Units

The set includes G4 filter material sheets made of high-quality synthetic filtering media. Classification according to ISO 16890: Coarse 65%. 

Filtering material sheets are for installation in filter frames only.

G4 filters are designed to protect the air handling unit and ventilation system from contamination by larger particles like dust, bugs, puff. Captures part of larger pollen but does not ensure full protection from all the pollen variations.

The main advantages of the G4 filters are low resistance and attractive price. G4 filters will serve longer than M5-F9 filters and will lead to lower energy consumption and sound emissions during operation.

The filtering efficiency of the G4 filter:

  • Coarse particles: >65% (dust, pollen)
  • PM10 particles: <35% (mold spores, animal dander)
  • PM2.5 particles: - (combustion particles)
  • PM1 particles: - (solid smog particles, virus carriers)

Filter construction:

  • Type: filtering material sheets.
  • Filtering material: high-quality thick synthetic media (premium, SANDLER AG).
  • Filtering material corresponds to hygienic requirements (resistant to microorganisms' growth). Certified according to VDI 6022 standard (Germany).

Replacement period: replacement period depends on outdoor air contamination. Filtering material sheets can be carefully cleaned using a vacuum cleaner every 2-3 months and must be replaced after the 3rd cleaning.

Additional information:

  • Packing: filters are packed in plastic film suitable for long-term storage.
  • Warranty: 2-year storage warranty if kept in proper condition and package.
  • Storage conditions: internal premises, RH<60%, low dustiness.
  • Made in the EU.

For an extra discount for higher quantities of filters please contact us directly.

The filter is high quality for analog, perfectly suited to your air handling unit. 

General recommendations:

  • Filter contamination is monitored by the timer in the control device. Filter change alerts are shown in the control panel or the mobile application. 
  • Filter change indication works as a reminder. AHU will operate despite this warning. 
  • The replacement period depends on outdoor air contamination. You might be needed to replace filters up to 1.5-2 times more frequently, if you live near intense traffic roads, paved roads, construction sites, industrial areas, working fields, etc. 
  • Most manufacturers recommend changing filters at least twice a year: before and after the heating season. 
  • Recommended replacement terms: activated carbon filters: up to 3 months, F7 filter - 4-6 months, M5, G4 filters - 5-8 months. Energy-efficient filters last 1.3-2 times longer. F7, F8, and F9 filter servicing terms can be prolonged up to 2-3 months if an additional G4 class prefilter is being used in the ventilation system. 
  • The extracted air filter can be changed less frequently, if you are using efficient F7, F8, F9, or activated carbon filters for outdoor air filtration.  
  • Panel/pocket filters are single-use only. Vacuuming or cleaning will not provide the desired effect, only can damage the filter. Efficient filtering material captures small particles inside and it clogs the filter. 
  • Wire-framed filters and filtering materials can be vacuumed up to 3 times before replacement if the user manual allows it.
  • Keep the flanges of your new ventilation unit covered before its first launch, in order to avoid quick filter contamination. 

Universal instruction

  • Always check the user manual if changing filters for the first time. 
  • Before proceeding turn off the ventilation unit and wait until the fan stops rotating completely.
  • Remove the front cover or filter cover.
  • Remove old filters.
  • Clean the unit with a vacuum cleaner and clean filter holders with wet wipes.
  • It is recommended to check other AHU components also: rotor belt, heat exchanger, fan impellers, etc. And clean if necessary.
  • Check the airflow direction before placing the new filters. Filters have airflow arrows on the labels they must match airflow direction. Usually, filters are installed before the heat exchanger, so arrows must point toward the center. However, if 3 filters are used there might be exceptions: if F7 or F8 filter is on the opposite side of the heat exchanger from that G4 filter, the airflow must point away from the heat exchanger. Most manufacturers placed arrows on the ventilation unit in order to install filters correctly. If filters are installed in the opposite direction, pressure resistance may increase up to 15%.
  • If you have filters of different efficiencies, e.g. F7 and G4. F7 filters must be installed on the Outdoor air side, and G4 on the Extract air side. The manufacturer marks them nearby duct connection flanges. Usually, the outdoor air duct is insulated and the extract air duct is not. Also, you may check the user manual, but pay attention, that it might be the right and left versions on the unit.
  • After installing new clean filters put the cover back. Then turn the device on.
  • Also, you will need to restart the filter timer on the control device according to user manual instructions.

Do not operate the air handling unit without filters, it will clog your heat exchanger and contaminate the ventilation system. Also, your warranty will be void.

Contaminated filters provide higher airflow resistance, and it lead to lower airflow volumes, higher energy consumption, and higher sound emissions. Change them on time and the ventilation unit will operate longer.

We are keen to supply you with top-quality air filters for the perfect indoor climate at the best price. We offer more than just a filter:

  • Experience and professional support: our consultants have long-term experience in HVAC production and service fields.
  • Wide range:  multiple options, including activated carbon, and energy-efficient filters for the most AHUs.
  • Fast delivery: over 40000 filters in our production warehouse are ready to be shipped next/same working day.
  • Quality materials:  filtering materials are made by leading companies such as SANDLER AG and have high efficiency and dust-holding capacity.
  • Top quality: all the filters, including of G4 class are glued to the frame to ensure maximum airtightness. 
  • Low prices: due to the short supply chain and high volumes we offer probably the best prices for quality filters in the EU.
  • Made in the EU. Over 85% percent of the ventilation filters sold in the EU are made in China from low-quality materials. 
  • Tested efficiency. Filters are tested in an accredited laboratory in Germany according to ISO16890 standards 

         

Filter is a replaceable component of any ventilation equipment therefore sustainable production and logistics play a key role.

Production:

  • High-quality 3-ply filtering material has a larger dust-holding capacity. Therefore, filters serve longer, and less material can be used in production.
  • We do not use glass fiber material in filters. Glass fiber is fragile, potentially hazardous, and non-recyclable.
  • Panel filter frames are made of moisture-resistant cardboard. The supplier uses the maximum possible amount of recycled cardboard production.
  • Energy in production plants comes from renewable sources.
  • Filter frames for certain Zehnder ComfoAir models are made of eco plastic with organic materials content of more than 80%.
  • Offer filter options made of energy-efficient materials, with 1.3-2 times longer replacement periods.
  • Due to patented technology, we use 30-50% less glue than used in other alternative filters.

 

Shorter delivery distance:

  • Materials for production are made by factories located in the EU countries.
  • Filers made in the EU (more than 80% of filters in the market are made in China or other Asian countries).
  • We deliver directly from the production warehouse.

We are constantly searching the ways to provide more sustainability to your filter!

PFAS chemicals have been used in a wide range of products since the 1940s. PFAS can migrate into soil, water and air during production or use. Most of these chemicals are practically non-degradable. A number of scientific studies indicate that PFAS chemicals may pose a risk to human and animal health.

Major health risks

Main products containing PFAS

CleanFilter filters are manufactured of certified high quality synthetic filtering material free of PFAS compounds.

  • Healthier indoor air. PFAS chemicals do not get into the air and do not spread throughout your rooms. 
  • Complies with the latest standards. The filters comply with current safety requirements and pending legislation relating to PFAS materials.
  • Excellent performance. Synthetic filter material offers durability and performance without the need for additional additives.
  • Environmental protection. By choosing PFAS-free filters, you are contributing to reducing environmental pollution and protecting public health.

Vores filtre er alternative produkter af høj kvalitet og er ikke fremstillet af de oprindelige producenter af ventilationsaggregater eller på deres vegne. Alle anvendte varemærker er udelukkende til identifikationsformål for at angive kompatibilitet. Vores filtre overholder ISO 16890-standarderne, er fremstillet af certificerede tyske materialer, og deres effektivitet er uafhængigt testet i eksterne laboratorier. Derudover er vores filtermaterialer fri for PFAS og andre skadelige stoffer, hvilket sikrer, at luften i dine lokaler forbliver sund og sikker. Alle vores filtre er udelukkende fremstillet i EU.